123
8024638/AE00/V1-0/2019-09| SICK
S E R V I C E M A N U A L | MCS200HW
Subject to change without notice
REPAIRS
5
4
Loosen the fastening screws of the heating garland:
▸
Cable conduit fastening clip with a 2.5 Allen key.
▸
Thermostatic switch fastening screw with a 2.5 mm Allen key.
▸
Ground fastening screw with a Phillips screwdriver.
5
Remove the heating garland.
Fig. 191: Heating garland
6
Remove heating cartridges from the heating garland:
1
Open the contact plug:
▸
Carefully lever open the clamps of the contact plug with a slotted screwdriver
(3 pieces).
Fig. 192: Opening the contact plug
▸
Loosen the screws of the fastening clip inside with a slotted screwdriver (2 pieces).
Fig. 193: Contact plug, assignment (example)
1
Fastening clip
2
Leads for thermostatic switches (2) and heating cartridges (4)
3
Grounding