MAINTENANCE
Fig. 19: Cell inlet filter, spare parts
12
Fit a new O-ring (black) on the outside.
Fig. 20: Cell inlet filter, O-ring, outer
13
Disconnect the nozzle on the cell with a 5 mm Allen key (
see Fig. 17 “Cell inlet filter,
).
14
Replace the spring washer of the nozzle.
15
Screw the nozzle tight.
16
Attach the cell inlet filter to the cell with new screws.
17
Fasten hose connections.
18
Close the cell cover and screw tight.
1 Sintered metal washer
2 Lock washer
3 O-ring, white
4 O-ring, black
5 Cell inlet filter
Keep the nozzle for reassembly.
Observe the sequence:
First put the spring washer, then the washer on the screw.