143
8024638/AE00/V1-0/2019-09| SICK
S E R V I C E M A N U A L | MCS200HW
Subject to change without notice
REPAIRS
5
1
Remove the electronics unit (
see Chapter “Removing and fitting the electronics unit”,
).
2
Loosen the fastening screws of the upper electronics unit with a Phillips screwdriver:
▸
Top fastening screws (2 pieces).
▸
Rear fastening screws (2 pieces).
Fig. 236: Upper electronics unit, fastening screws 1
Fig. 237: Upper electronics unit, fastening screws 2
3
Loosen the ribbon cable and white connection cable:
▸
To release from the lower slots, slightly lift the upper drawer and shift it backwards.
Fig. 238: Disconnecting the upper electronics unit cable
4
Remove the upper electronics unit.
1
Fastening screw
1
Fastening screw
Document the plug positions of the fuse cables for reassembly. E.g. with a photo or use
the circuit diagram.