SEL-387 Relay Command Summary
CON
n
Control Relay Word bit RB
n
(Remote Bit
n
;
n
= 1 through 16).
Execute
CON
n
and the relay responds:
CONTROL RBn
. Reply with one of the following:
SRB
n
set Remote Bit
n
(assert RB
n
)
CRB
n
clear Remote Bit
n
(deassert RB
n
)
PRB
n
pulse Remote Bit
n
[assert RB
n
for one processing interval (1/8-cycle)].
COPY
m n
Copy settings and logic from setting Group
m
to Group
n
.
DAT
Show date presently in the relay.
DAT m/d/y
Enter date in this manner if Date Format setting DATE_F = MDY.
DAT y/m/d
Enter date in this manner if Date Format setting DATE_F = YMD.
EVE
n
Show standard event report number
n
, with 1/4-cycle resolution.
Attach
S8
for 1/8-cycle resolution.
EVE D
n
Show digital data event report number
n
, with 1/4-cycle resolution.
Attach
S8
for 1/8-cycle resolution.
EVE DIF1
n
Show differential element 1 event report number
n
, with 1/4-cycle resolution.
Attach
S8
for 1/8-cycle resolution.
EVE DIF2
n
Show differential element 2 event report number
n
, with 1/4-cycle resolution.
Attach
S8
for 1/8-cycle resolution.
EVE DIF3
n
Show differential element 3 event report number
n
, with 1/4-cycle resolution.
Attach
S8
for 1/8-cycle resolution.
EVE R
n
Show raw analog data event report number
n
, with 1/16-cycle resolution.
Attach
S
m
for 1/
m
-cycle resolution (
m
= 4, 8, 32, 64).
EVE T
Show event summary.
GRO
Display active setting group number.
GRO
n
Switch to Setting Group
n
. (Will not function if any SS
n
Relay Word bit is asserted.)
HIS
n
Show brief summary of the
n
latest event reports.
HIS C
Clear the brief summary and corresponding standard event reports.
ID
Display variety of identification and configuration information about the relay.
INI
INITIO
command reports the number and type of I/O boards in the relay. In Access Level 2, confirms that I/O
boards are correct.
IRI
Force synchronization attempt of internal relay clock to IRIG-B time-code input.
MET
k
Display metering data, in primary amperes. Enter number
k
to scroll metering
k
times on screen.
MET D
k
Display demand metering data, in primary amperes. Enter number
k
to scroll metering
k
times on screen.
MET H
Generate harmonic spectrum report for all input currents, showing first to fifteenth harmonic levels in secondary
amperes.
MET DIF
k
Display differential metering data, in multiples of TAP. Enter number
k
to scroll metering
k
times on screen.
MET P
k
Display peak demand metering data, in primary amperes. Enter number
k
to scroll metering
k
times on screen.
MET RD
n
Reset demand metering values (
n
= 1, 2, 3, 4, A).
MET RP
n
Reset peak demand metering values (
n
= 1, 2, 3, 4, A).
MET SEC
k
Display metering data (magnitude and phase angle), in secondary amperes. Enter number
k
to scroll metering
k
times on screen.
MET T
Report temperature values of up to 24 RTD inputs (SEL-387-5 and SEL-387-6 Relays only).
OPE
n
Assert the OC
n
Relay Word bit. Used to open breaker
n
if OC
n
is assigned to an output contact. JMP6B has to be
in place to enable this command.
PAS
Show existing Access Level 1, B, and 2 passwords.
Access Level 2
Commands
The Access Level 2 commands primarily allow the user to change settings or operate relay
parameters and output contacts. All Access Level 1 commands can also be executed from Access
Level 2. The screen prompt is: =>>
Summary of Contents for SEL-387-0
Page 6: ...This page intentionally left blank ...
Page 12: ...This page intentionally left blank ...
Page 50: ...This page intentionally left blank ...
Page 200: ...This page intentionally left blank ...
Page 248: ...This page intentionally left blank ...
Page 380: ...This page intentionally left blank ...
Page 422: ...This page intentionally left blank ...
Page 440: ...This page intentionally left blank ...
Page 458: ...This page intentionally left blank ...
Page 516: ...This page intentionally left blank ...