4.41
Date Code 20170601
Instruction Manual
SEL-387-0, -5, -6 Relay
Control Logic
Relay Word Bits
51NC1
Windings 1 and 2 residual inverse-time
O/C element picked up
22
51NC1R
Windings 1 and 2 residual inverse-time O/C element is reset
22
51NC1T
Windings 1 and 2 residual inverse-time
O/C element timed out
22
51NC2
Windings 3 and 4 residual inverse-time
O/C element picked up
23
51NC2R
Windings 3 and 4 residual inverse-time O/C element is reset
23
51NC2T
Windings 3 and 4 residual inverse-time
O/C element timed out
23
51P1
Winding 1 phase inverse-time O/C element picked up
2
51P1R
Winding 1 phase inverse-time O/C 51P1 element is reset
2
51P1T
Winding 1 phase inverse-time O/C element timed out
2
51P2
Winding 2 phase inverse-time O/C element picked up
6
51P2R
Winding 2 phase inverse-time O/C 51P2 element is reset
6
51P2T
Winding 2 phase inverse-time O/C element timed out
6
51P3
Winding 3 phase inverse-time O/C element picked up
10
51P3R
Winding 3 phase inverse-time O/C 51P3 element is reset
10
51P3T
Winding 3 phase inverse-time O/C element timed out
10
51P4
Winding 4 phase inverse-time O/C element picked up
14
51P4R
Winding 4 phase inverse-time O/C 51P4 element is reset
14
51P4T
Winding 4 phase inverse-time O/C element timed out
14
51PC1
Windings 1 and 2 phase inverse-time O/C element picked up
22
51PC1R
Windings 1 and 2 phase inverse-time O/C element is reset
22
51PC1T
Windings 1 and 2 phase inverse-time O/C element timed out
22
51PC2
Windings 3 and 4 phase inverse-time O/C element picked up
23
51PC2R
Windings 3 and 4 phase inverse-time O/C element is reset
23
51PC2T
Windings 3 and 4 phase inverse-time O/C element timed out
23
51Q1
Winding 1 neg.-seq. inverse-time O/C element picked up
5
51Q1R
Winding 1 neg.-seq. inverse-time O/C 51Q1 element is reset
5
51Q1T
Winding 1 neg.-seq. inverse-time O/C element timed out
5
51Q2
Winding 2 neg.-seq. inverse-time O/C element picked up
9
51Q2R
Winding 2 neg.-seq. inverse-time O/C 51Q2 element is reset
9
51Q2T
Winding 2 neg.-seq. inverse-time O/C element timed out
9
51Q3
Winding 3 neg.-seq. inverse-time O/C element picked up
13
51Q3R
Winding 3 neg.-seq. inverse-time O/C 51Q3 element is reset
13
51Q3T
Winding 3 neg.-seq. inverse-time O/C element timed out
13
51Q4
Winding 4 neg.-seq. inverse-time O/C element picked up
17
51Q4R
Winding 4 neg.-seq. inverse-time O/C 51Q4 element is reset
17
51Q4T
Winding 4 neg.-seq. inverse-time O/C element timed out
17
5HB1
Fifth-harmonic block asserted for differential element 1
19
5HB2
Fifth-harmonic block asserted for differential element 2
19
Table 4.11
Relay Word Bits Sorted Alphabetically
(Sheet 6 of 13)
Bit
Definition
Row
Summary of Contents for SEL-387-0
Page 6: ...This page intentionally left blank ...
Page 12: ...This page intentionally left blank ...
Page 50: ...This page intentionally left blank ...
Page 200: ...This page intentionally left blank ...
Page 248: ...This page intentionally left blank ...
Page 380: ...This page intentionally left blank ...
Page 422: ...This page intentionally left blank ...
Page 440: ...This page intentionally left blank ...
Page 458: ...This page intentionally left blank ...
Page 516: ...This page intentionally left blank ...