Remote Commands
R&S
®
EVSG1000
247
User Manual 1178.6227.02 ─ 04
VIEW_VOR?
VIEW_VOR
<View type>
This command selects a view type for the VOR mode.
Parameters:
<View type>
MAIN | DIST | ID | LOG
Available views for VOR mode.
Return values:
<State>
READY.
The command was executed successfully.
VOR_DEM_BW?
VOR_DEM_BW
<Bandwidth>
Gets or sets the demodulator Bandwidth in "ILS MB" mode.
Parameters:
<Bandwidth>
1KHZ | 3KHZ | 6KHZ | 10KHZ | 18KHZ | 25KHZ | 36KHZ |
50KHZ
Return values:
<State>
READY.
The command was executed successfully.
13.4.2
Retrieving VOR Results
The following commands are required to retrieve results from VOR measurements.
Useful commands for retrieving results described elsewhere:
●
●
Remote commands exclusive to VOR results:
VOR Mode