GBAS/SCAT-I Mode (Options R&S
EVSG-K4/-K5)
R&S
®
EVSG1000
146
User Manual 1178.6227.02 ─ 04
Further control elements implement loops which repeat sequences for a number of
repetitions ("for"-loop) or while there is enough data left ("while"-loop).
Control elements can also contain references to previous elements, that is: to results
obtained in previous instruction steps. References are defined using the element's
unique identifier, which is a mandatory part of each element.
Using links and loops, the parser can navigate through the entire bitstream.
Parser results
The result of the interpreted bitstream is a comma-separated list of values which is dis-
played in the "Message" view (see
Recording GBAS data
When you record and export the results of a GBAS measurement, all measured values
and the bitstream for each record are stored as a comma-separated list. This basic
CSV file contains a data link for each record in the list. The link points to a further CSV
file which contains all human-readable texts for that record. All data files for the current
recording are stored in a sub-directory that is exported together with the basic CSV file.
The file with the human-readable text values contains the data that is displayed in the
"Message" view.
Example:
One row of data from the basic CSV file for list number 20 (
gbas_rx1_list20.csv
):
1,,3,18.09.2018,14:29:57.844,D,108.0000,0.000,-8.15,-4.63,-,7.0,CMJ ,NOK,4,NOK,
0.0e+00,882,-.-,-.-,-.-,20.553,481.0,00° 00.00000000' N,00° 00.00000000' E,0.00,0.00,
--.--.----,--.--.--.---,0,NO GPS,NO GPS,--,--,--,MAN:Norm,0,1 82 30 00 55 05 4B 30 20
3A 94 0F F0 40 60 30 F2 98 C0 C8 40 28 E0 61 47 5D 48 09 7B C9 00 AD D8 33 3C BF 34
07 40 AA 81 34 80 26 00 B2 15 A5 45 26 13 94 08 F0 40 60 30 86 90 A8 04 70 28 E0 3D
83 ED 48 38 C5 E9 00 4B D8 DF 46 40 3C 21 BF 8C 81 B4 80 26 00 EB 05 B2 F5 26 13 D9
7F C0 EA A1 A4 3D 54 89 D8 00 00 ,=HYPERLINK("gbas_rx1_list20/MSG000003_D.csv")
Extract of data file
gbas_rx1_list20/MSG000003_D.csv
:
Name,Type,bits used,Value,Unit,binary
Power Stabilization,fixed,15,OK,,000000000000000
Sync. and Amb. Resolution,fixed,48,OK,,010001111101111110001100011101100000011110010000
Table 7-2: Output in Message view table
Data Content
Bits used
Value
Binary
Power stabilization
15
OK
000000000000000
Sync. and ambiguity resolu-
tion
48
OK
0100011111011111100011000111011000
00011110010000
Message XML Interface