
Remote Commands
R&S
®
EVSG1000
204
User Manual 1178.6227.02 ─ 04
SETUP:DDM_RANGE_LLZ
<Channel>,<Range>
This command selects a predefined DDM range. This command is active for analog
output in ILS localizer mode.
Parameters:
<Channel>
1
Selects input source for channel 1.
2
Selects input source for channel 2.
<Range>
Range:
1 to 4
Return values:
<State>
READY.
The command was executed successfully.
SETUP:DDM_RANGE_GS
<Channel>,<Range>
This command selects a predefined DDM range. The command is active for analog
output in ILS glidepath mode.
Parameters:
<Channel>
1
Selects input source for channel 1.
2
Selects input source for channel 2.
<Range>
Range:
1 to 4
Return values:
<State>
READY.
The command was executed successfully.
SETUP:DEMOD_OUT?
SETUP:DEMOD_OUT
<Mode>
Gets or sets the Demodulation-Out mode.
Parameters:
<Mode>
OFF
No output signal is provided.
RX_1_BB_OUT
Output provided by the BB Out connector on receiver board
"RX1" or "RX 2".
RX_2_BB_OUT
Output provided by the BB Out connector on receiver board
"RX1" or "RX 2".
Return values:
<State>
READY.
The command was executed successfully.
Common Instrument and Measurement Setup