Remote Commands
R&S
®
EVSG1000
245
User Manual 1178.6227.02 ─ 04
Return values:
<Time>
Length of time that passes between two transmitted dashes for
the outer marker.
Default unit: ms
Manual operation:
See
ID_F1300_GAP
Queries the dash-dot gap time of 1300 Hz signal in "ILS MB" mode.
Return values:
<Time>
Length of time that passes between a transmitted dot and a
dash for the middle marker.
Default unit: ms
Manual operation:
See
ID_F3000_GAP
Queries the dot-dot gap time of 3000 Hz signal in "ILS MB" mode.
Return values:
<Time>
Length of time that passes between two transmitted dots for the
inner marker.
Default unit: ms
Manual operation:
See
13.3.4
Deprecated Commands
The following commands are maintained for compatibility with former
Rohde
&
Schwarz analyzers only. For new remote control programs, use the com-
Chapter 13.3.1, "Configuring ILS MB Measurements"
Chapter 13.11, "Data Management"
FA0
This command stops the continuous output that was started with FA2.
Return values:
<State>
READY.
The command was executed successfully.
ILS Marker Beacon (MB) Mode