Remote Commands
R&S
®
EVSG1000
240
User Manual 1178.6227.02 ─ 04
The command FA0 stops the output.
Return values:
<State>
READY.
The command was executed successfully.
FA3
The same output format as
on page 239, but the values are only transmitted when
triggered by another FA3 command. Note that this behavior is different from EVS200,
where the trigger is an arbitrary ASCI character.
Return values:
<State>
READY.
The command was executed successfully.
FA4
The same as
on page 239, but output is preceded by a timestamp.
Return values:
<State>
READY.
The command was executed successfully.
FA5
The same as
on page 239, but output is preceded by the time in ms since the FA5
is started.
The command FA0 stops the output.
Return values:
<State>
READY.
The command was executed successfully.
GSLLZ
Queries if the R&S
EVSG1000 is in GS or LOC mode.
Return values:
<mode>
GS | LOC
Shows the current mode.
13.3
ILS Marker Beacon (MB) Mode
The following commands are required to configure and perform measurements in the
ILS Marker beacon mode.