Graphic Measurement Modes
R&S
®
EVSG1000
111
User Manual 1178.6227.02 ─ 04
●
Measurement mode
The currently active measurement mode on the active receiver board, e.g. "AF
Spectrum". See
Chapter 4.3, "Measurement Mode"
●
"RF Freq"
Nominal measurement frequency of the RF signal, see
●
Frequency range
"AF Center", "AF Span", "AF Start", "AF Stop"
The swept frequency range, see
Chapter 6.1.1, "Configuring the Frequency
●
RF attenuation ("Att")
The used attenuation mode; see also
●
Resolution Bandwidth ("RBW")
Resolution bandwidth with which the measurement is performed. See
Remote command to select RF Spectrum mode:
Remote command to retrieve trace results:
6.3.1
Configuring the Frequency Range
Access
: [CH F]
Access VNC
: [q]
The following settings configure the frequency range of the spectrum, that is: the x-
axis.
Define the frequency range to be displayed using one of the following methods:
●
: the center frequency is displayed in the center of the x-axis,
with half the span to the either side
●
: the x-axis starts with the start frequency and ends with the
stop frequency
RF Freq
Configures the nominal frequency of the measurement. The configured value is dis-
played as "RF Freq" in the measurement settings area.
Remote command:
AF Spectrum Mode (Option R&S