8. COMMUNICATION DATA LIST
IMR02E20-E1
71
Continued from the previous page.
No. Name
Iden-
tifier
Chan-
nel
Resister address
Digits
Attri-
bute
Struc-
ture
Data range
Factory
set value
HEX
DEC
24
Module address
assignments for CT
input
BX CH1
CH192
635C
641B
25436
25627
7 R/W
1
C
0 to 99
0
25
Module channel
assignments for CT
input
BY CH1
CH192
641C
64DB
25628
25819
7 R/W
1
C
1 to 99
1
26
Load factor
conversion method
2
IC CH1
CH192
64DC
659B
25820
26011
1 R/W
1
C
0: Mean conversion
1: Root mean squared value
conversion
0
27
CT Interval time
VH
CH1
CH16
659C
65AB
26012
26027
7 R/W
1
M
0 to 250 ms
10
28
Unused
65AC
666B
26028
26219
1
When the set lock (Identifier: LK, Resister address: 5E0CH to 5E1BH) is set to “0: Unlock” (the RUN/STOP transfer of the COM-ML becomes
STOP), writing data is possible.
2
For monitoring using “0: Mean conversion” or “1: Root mean squared value conversion,” the following settings are required:
Module address assignments for CT input must be set.
Module channel assignments for CT input must be set.
The heater break alarm (HBA) value must be set to other than “0.0.”