8. COMMUNICATION DATA LIST
IMR02E20-E1
40
Continued from the previous page.
No.
Name
Iden-
tifier
Chan-
nel
Register address
Digits
Attri-
bute
Struc-
ture
Data range
Factory
set value
HEX DEC
7
Current transformer
(CT) input value
monitor
M3 CH1
CH64
034C
038B
844
907
7 RO
C CTL-6-P-N:
0.0 to 30.0 A
CTL-12-S56-10L-N:
0.0 to 100.0 A
8
Set value (SV)
monitor
MS CH1
CH64
038C
03CB
908
971
7 RO
C Setting limiter low to
Setting limiter high
9
Remote setting (RS)
input value monitor
S2 CH1
CH64
03CC
040B
972
1035
7 RO
C Setting limiter low to
Setting limiter high
10 Burnout
state
monitor B1 CH1
CH64
040C
044B
1036
1099
1 RO
C 0: OFF
1: ON
11
Event 1 state monitor
AA
CH1
CH64
044C
048B
1100
1163
1 RO
C 0: OFF
1: ON
If the Event 3 type is temperature
rise completion, check the
temperature rise completion state
in the comprehensive event state
(Identifier: AJ, Register address:
023CH to 027BH).
(The Event 3 state monitor does
not turn ON.)
12
Event 2 state monitor
AB
CH1
CH64
048C
04CB
1164
1227
1 RO
C
13
Event 3 state monitor
AC
CH1
CH64
04CC
050B
1228
1291
1 RO
C
14
Event 4 state monitor
AD
CH1
CH64
050C
054B
1292
1355
1 RO
C
15
Heater break alarm
(HBA) state monitor
AE CH1
CH64
054C
058B
1356
1419
1 RO
C 0: OFF
1: ON
16 Output
state
monitor
Q1 CH1
CH16
058C
059B
1420
1435
7 RO
M
RKC communication
Least significant digit:
OUT1
2nd digit: OUT2
3rd digit: OUT3
4th digit: OUT4
5th digit to Most significant digit:
Unused
Data 0: OFF
1: ON
Modbus
Bit data
Bit 0: OUT1
Bit 1: OUT2
Bit 2: OUT3
Bit 3: OUT4
Bit 4 to Bit 15: Unused
Data 0: OFF
1: ON
[Decimal number: 0 to 15]
Valid only for time-proportional control
output.
17
Memory area soak
time monitor
TR CH1
CH64
059C
05DB
1436
1499
7 RO
C 0 minutes 00 seconds to
199 minutes 59 seconds:
RKC communication:
0:00 to 199:59 (min:sec)
Modbus: 0 to 11999 seconds
0 hours 00 minutes to
99 hours 59 minutes:
RKC communication:
0:00 to 99:59 (hrs:min)
Modbus: 0 to 5999 minutes
Data range of Area soak time can be
selected on the Soak time unit.
Continued on the next page.