DESCRIPTION OF PROGRAMMING PARAMETERS
Screen Description
Default
value
Range
Function
Set on
RUN
Note
: Comes from the previous page.
OPT.
DESCR.
FUNCTION
14
TIMER
Adds 1 each time a user
sequence completes a
loop.
A sets the timer value.
B enables or disables the
timer. If B = 0, the timer is
enabled.
C defines the timer
operation mode. If C = 0,
the output will be 1 when
timer value equals A. if C
= 1, the output is the timer
current value. When A
equals the timer value,
the counter is reset.
15
LIMIT
Sets a limit for the A
parameter.
If input to A is between B
and C, output the input to
A. If input to A is larger
than B, output B. If input
of A is smaller than C,
output C.
B must be greater than or
equal to C.
16
AND
Outputs the result of the
AND operation, (A and B)
and C.
17
OR
Outputs the result of the
OR operation, (A | B) | C.
18
XOR
Outputs the result of the
XOR operation, (A ^ B) ^
C.
Note
: Continues in the next page.