SD300
POWER ELECTRONICS
144
DESCRIPTION OF PROGRAMMING PARAMETERS
Screen Description
Default
value
Range
Function
Set on
RUN
Cn.24
Independent
controller
integral gain 2
(*)
1.0 to
1000.0%
Set the integral gain 2 of a separate
controller.
YES
Cn.25
Integral time
sensorless
controller
(*)
10 to
999ms Sensorless speed controller integral gain 0. YES
Cn.26
Flux estimator
proportional
gain
(*)
1 to
200% Sensorless vector control requires the rotor
flux estimator. Use these parameters to
adjust flux estimator gain
YES
Cn.27
Flux estimator
integral gain
(*)
1 to
200%
YES
Cn.28
Speed
estimator
proportional
gain 1
(*)
0 to
32767
Adjusts speed estimator gain for sensorless
vector control:
•
At low speed (10Hz or lower), increase
the value of Cn.29 by increments of 5.
•
At mid speed (30 Hz or higher), increase
the value of Cn.28 by increments of 500.
If the parameter setting is too extreme,
over current trip may occur at low speed.
YES
Cn.29
Speed
estimator
integral gain 1
(*)
100 to
1000
YES
Cn.30
Speed
estimator
integral gain 2
(*)
100 to
10000
YES
Cn.31
Sensorless
cont.
proportional
gain
(*)
10 to
1000 Adjusts the P and I gains of the sensorless
current controller.
If the value of Cn.10 is high, an overcurrent
trip at start can occur. In this case, reduce
the value of Cn.31 by decrements of 10.
YES
Cn.32
Sensorless
cont. integral
gain
(*)
10 to
1000
YES
[18] Displayed when dr.9 is set to 4 (S-less1) and Cn.20 is set to 1 (YES).
(*) Estos valores dependen del ajuste del motor.
Summary of Contents for SD 300 Series
Page 1: ...SD300 GETTING STARTED MANUAL LOW VOLTAGE VARIABLE SPEED DRIVE ...
Page 2: ......
Page 3: ...Variable Speed Drive Getting Started Manual Edition February 2019 SD30IM01GI Rev G ...
Page 159: ...POWER ELECTRONICS SD300 DESCRIPTION OF PROGRAMMING PARAMETERS 157 Power off delay ...
Page 174: ...SD300 POWER ELECTRONICS 172 DESCRIPTION OF PROGRAMMING PARAMETERS TI configuration ...
Page 352: ......
Page 353: ......