POWER ELECTRONICS
SD300
DESCRIPTION OF PROGRAMMING PARAMETERS
171
Screen Description Default
value
Range
Function
Set
on
RUN
In.98
TI noise
reduction
level
0.04%
0.04 to
10.00%
This parameter is used to reduce noise in the
TI input signal. The quantification value is
defined as the input maximum percentage
value.
YES
In.99
Input mode
setting
00
00 to 11
Software status. Set each bit to 0 or 1
according to the following table:
BIT
DESCR.
00
V2, NPN
01
V2, PNP
10
I2, NPN
11
I2, PNP
NO
Multifunction relay configuration
Inputs configuration for acceleration / deceleration