SD300
POWER ELECTRONICS
248
MODBUS COMMUNICATION
Screen
Description
Modbus
Decimal
Address
Hexadecimal
Range
Modbus Range
Cn.34
PM Q-axis back-EMF
estimated gain (%)
45154
0h1422
0
–
300.0%
0
–
300.0
Cn.35
Initial pole position
estimation retry
45155
0h1423
0
–
10
0
–
10
Cn.36
Initial pole position
estimation interval
45156
0h1424
1
–
100ms
1
–
100
Cn.37
Initial pole position
estimation pulse
current (%)
45157
0h1425
10
–
100%
10
–
100
Cn.38
Initial pole position
estimation pulse
voltage (%)
45158
0h1426
100
–
4000
100
–
4000
Cn.39
PM dead-time range
(%)
45159
0h1427
50.0
–
200.0%
50.0
–
200.0
Cn.40
PM dead-time voltage
(%)
45160
0h1428
50.0
–
200.0%
50.0
–
200.0
Cn.41
PM speed estimator
proportional gain
45161
0h1429
0
–
32000
0
–
32000
Cn.42
PM speed estimator
integral gain
45168
0h1430
0
–
32000
0
–
32000
Cn.43
PM speed estimator
proportional gain 2
45169
0h1431
0
–
32000
0
–
32000
Cn.44
PM speed estimator
integral gain 2
45170
0h1432
0
–
32000
0
–
32000
Cn.45
Speed estimator
feedforward high
speed range (%)
45171
0h1433
0
–
1000%
0
–
1000
Summary of Contents for SD 300 Series
Page 1: ...SD300 GETTING STARTED MANUAL LOW VOLTAGE VARIABLE SPEED DRIVE ...
Page 2: ......
Page 3: ...Variable Speed Drive Getting Started Manual Edition February 2019 SD30IM01GI Rev G ...
Page 159: ...POWER ELECTRONICS SD300 DESCRIPTION OF PROGRAMMING PARAMETERS 157 Power off delay ...
Page 174: ...SD300 POWER ELECTRONICS 172 DESCRIPTION OF PROGRAMMING PARAMETERS TI configuration ...
Page 352: ......
Page 353: ......