DESCRIPTION OF PROGRAMMING PARAMETERS
Screen Description
Default
value
Range
Function
Set on
RUN
Cn.55
Forward
negative
torque limit
180.0%
0.0 to
200.0%
The user can set the forward regeneration
operation torque limit whenever the torque
limit reference has been set as LOCAL
YES
Cn.56
Reverse
positive torque
limit
180.0%
0.0 to
200.0%
The user can set the reverse motoring
operation torque limit whenever the torque
limit reference has been set as LOCAL
YES
Cn.57
Reverse
negative
torque limit
180.0%
0.0 to
200.0%
The user can set the reverse regeneration
operation torque limit whenever the torque
limit reference has been set as LOCAL
YES
Cn.62
Speed limit
reference
LOCAL
0 to 8
Select the source to introduce the speed
limit reference.
OPT. DESCR. FUNCTION
0
LOCAL
Reference will be given by
keypad and will be set in
dr.1.
2
V1
Reference
will
be
introduced through the
voltage analog input 1.
4
V2
Reference
will
be
introduced through the
voltage analog input 2.
5
I2
Reference
will
be
introduced through the
current analog input 2.
6
MOD
BUS
The reference will be
introduced
through
Modbus.
7
COMM
S
The reference will be
introduced through the
communications.
8
PLC
The common area can be
linked with user sequence
output and can be used as
command.
NO
Cn.63
Forward
speed limit
60.00Hz
0.00 to
400.00H
z
The user can set the forward speed limit
whenever the speed limit reference has
been set as LOCAL.
YES
Cn.64
Reverse
speed limit
60.00Hz
0.00 to
400.00H
z
The user can set the reverse speed limit
whenever the speed limit reference has
been set as LOCAL.
YES
Summary of Contents for SD 300 Series
Page 1: ...SD300 GETTING STARTED MANUAL LOW VOLTAGE VARIABLE SPEED DRIVE ...
Page 2: ......
Page 3: ...Variable Speed Drive Getting Started Manual Edition February 2019 SD30IM01GI Rev G ...
Page 159: ...POWER ELECTRONICS SD300 DESCRIPTION OF PROGRAMMING PARAMETERS 157 Power off delay ...
Page 174: ...SD300 POWER ELECTRONICS 172 DESCRIPTION OF PROGRAMMING PARAMETERS TI configuration ...
Page 352: ......
Page 353: ......