Introduction
1-12
Septum
– Silicone rubber material placed in the injection port through which the
injection is made. When the needle is withdrawn, the silicone rubber reseals,
thus not allowing any sample or carrier gas to escape.
Stationary phase
– The liquid or solid adsorbent portion of the column that
retains components passing through the GC column.
Subambient
– Below ambient temperature. The oven cools down below
ambient temperature with the use of either liquid nitrogen or liquid carbon
dioxide.
Syringes
– Precision dispensing devices used to deliver sample to the GC.
Liquid and gas syringes are available.
Tailing
– When a peak is not symmetrical or Gaussian shaped but the back end is
broadened, it is said to be tailing.
Temperature programming
– A technique commonly used to increase the rate of
elution of the components. After the sample is injected into the oven at a specific
temperature, the temperature program increases the oven temperature to the
prescribed temperature at a defined rate (in
°
C/min).
Unretained peak
– A component that is not retained by the column. The time
taken for an unretained sample to pass through the column is the same time as the
time taken for the carrier gas to pass through.
Velocity programming
– Programmed linear velocity where the PPC controller
interprets stored PPC programs as the average capillary column linear velocity
settings.
Summary of Contents for CLARUS 600 GC
Page 1: ...CLARUS 600 680 GC User s Guide GAS CHROMATOGRAPHY ...
Page 2: ......
Page 3: ...Clarus 600 680 GC User s Guide ...
Page 10: ...viii ...
Page 11: ...Introduction 1 ...
Page 12: ...Introduction 1 2 ...
Page 23: ...Touch Screen Navigation 2 ...
Page 24: ...Touch Screen Navigation 2 2 ...
Page 73: ...Using the Active Method 3 ...
Page 74: ...Using the Active Method 3 2 ...
Page 87: ...Clarus 600 680 User s Guide 3 15 The injector information displays ...
Page 119: ...Clarus 600 680 User s Guide 3 47 Setting the Timed Events 1 Touch the Events tab ...
Page 137: ...Setting Up the Detectors 4 ...
Page 138: ...Setting Up the Detectors 4 2 ...
Page 194: ...Setting Up the Detectors 4 58 2 The FPD page is now visible ...
Page 199: ...Clarus 600 680 User s Guide 4 63 4 The FPD tab page is now displayed ...
Page 230: ...Setting Up the Detectors 4 94 NOTE When Autozero is Off the output signal is never autozeroed ...
Page 231: ...Using the Method Editor 5 ...
Page 232: ...Using the Method Editor 5 2 ...
Page 248: ...Using the Method Editor 5 18 ...
Page 249: ...Using the Tools Menu 6 ...
Page 250: ...Using the Tools Menu 6 2 ...
Page 272: ...Using the Tools Menu 6 24 PID NPD ...
Page 273: ...Clarus 600 680 GC User s Guide 6 25 FPD Output Configured ...
Page 282: ...Using the Tools Menu 6 34 PPC Configure ...
Page 329: ...Setting up a Typical Analysis 7 ...
Page 330: ...Setting up a Typical Analysis 7 2 ...
Page 333: ...Clarus 600 680 GC User s Guide 7 5 ...
Page 354: ...Setting up a Typical Analysis 7 26 ...
Page 355: ...Index ...
Page 356: ...I 2 ...
Page 361: ......