3-30
3
4.
Inputs and outputs on connector X4
Connection
Interface Circuit (Input)
Input Circuit
SI
Connection to sequence input signals
Related
control mode
P
S
T
F
• Connect to contacts of switches and relays, or open collector output transistors.
• When you use contact inputs, use the switches and relays for micro current to avoid contact
failure.
• Make the lower limit voltage of the power supply (12 to 24V) as 11.4V or more in order to
secure the primary current for photo-couplers.
PI1
Connection to sequence input signals (Pulse train interface)
Related
control mode
P
S
T
F
(1) Line driver I/F (Input pulse frequency : max. 500kpps)
• This signal transmission method has better noise immunity.
We recommend this to secure the signal transmission.
(2) Open collector I/F (Input pulse frequency : max. 200kpps)
• The method which uses an external control signal power supply (VDC)
• Current regulating resistor (R) corresponding to V
DC
is
required in this case.
• Connect the specified resister as below.
• (R) should be placed close to the driver for effective noise reduction.
(3) Open collector I/F (Input pulse frequency : max. 200kpps)
• Connecting diagram when a current regulating resistor is not
used with 24V power supply.
12 to 24V
7
COM+4.7k
Ω
SRV-ON etc.
Relay
7
COM+4.7k
Ω
Relay
SRV-ON etc.
V
DC
12V
24V
Specifications
1k
Ω
1/2W
2k
Ω
1/2W
V
DC
–1.5
R+220
.=. 10mA
(1)
(2)
(3)
3 PULS1
4 PULS2
220
Ω
V
DC
R
5 SIGN1
6 SIGN2
220
Ω
2.2k
Ω
2.2k
Ω
R
1 OPC1
4 PULS2
220
Ω
24V
DC
2 OPC1
6 SIGN2
220
Ω
2.2k
Ω
2.2k
Ω
2.2k
Ω
2.2k
Ω
1 OPC1
4 PULS2
220
Ω
2 OPC1
6 SIGN2
220
Ω
2.2k
Ω
2.2k
Ω
2.2k
Ω
2.2k
Ω
13
13
13
Max.input voltage :
DC24V, Rated current : 10mA
represents twisted pair.