1-2
1
Before Using the Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When in T
rouble
7
Supplement
1
Before Using
the Products
6. Permissible Load at Output Shaft
Motor
L
L/2
P
A
M
B
Radial load (P) direction
Thrust load (A and B) direction
Unit : N (1kgf=9.8N)
Motor
series
Motor output
At assembly
During running
Radial thrust
Thrust load
Radial thrust
Thrust load A
and
B-direction
A-direction B-direction
MSME
50W, 100W
17
88
117.6
68.6
58.8
200W, 00W
92
17
196
25
98
750W
686
29
92
92
17
1.0kW, 1.5kW,
2.0kW, .0kW
980
588
686
90
196
.0kW, 5.0kW
78
MDME
1.0kW to 2.0kW
980
588
686
90
196
.0kW
78
.0kW
1666
78
980
5.0kW
MHME
1.0kW to 1.5kW
980
588
686
90
196
2.0kW to 5.0kW
1666
78
980
78
MGME
0.9kW
980
588
686
686
196
2.0kW
1666
78
980
1176
90
.0kW
2058
980
1176
170
Note
When the load point varies, calculate the permissible radial load, P (N) from the distance
of the load point, L (mm) from the mounting flange based on the formula of the right ta
-
ble, and make it smaller than the calculated result.
L
P
Motor
series
Motor
output
Formula of Load and
load point relation
Motor
series
Motor
output
Formula of Load and
load point relation
MSME
50W
P =
5
L+9
MDME
1.0kW to 2.0kW
P =
20580
L+1.5
100W
P =
905
L+59
.0kW
P =
688
L+1.5
200W
P =
195
L+6
.0kW
5.0kW
P =
26
L+19
00W
P =
1972
L+65.5
MGME
0.9kW
P =
957
L+1.5
750W
P =
70
L+77
2.0kW
P =
698
L+19
1.0kW to .0kW
P =
20090
L+1.5
.0kW
P =
8670
L+19
.0kW
5.0kW
P =
688
L+1.5
MHME
1.0kW to 1.5kW
P =
2255
L+1.5
2.0kW to 5.0kW
P =
6256
L+19
Summary of Contents for MINAS A5-series