4-53
1
Before
Using
the
Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When
in
Trouble
7
Supplement
Pr6.14
Title
Emergency stop time at alarm
Related
control mode
P S T F
Range
0 to 1000
Unit
1ms
Default
200
Set up the time allowed to complete emergency stop in an alarm condition. Exceeding this
time puts the system in alarm state.
When setup value is 0, immediate stop is disabled and the immediate alarm stop is enabled.
Pr6.15
Title
2nd over-speed level setup
Related
control mode
P S T F
Range
0 to 20000
Unit
r/min
Default
0
When the motor speed exceeds this setup time during emergency stop sequence in an
alarm condition, Err26.1 2nd overspeed protection will be activated.
The over-speed level becomes 1.2 times of the motor max. speed by setting up this to 0.
Pr6.17
*
Title
Front panel parameter writing selection
Related
control mode
P S T F
Range
0 to 1
Unit
—
Default
0
Specify the EEPROM writing procedure when parameter is edited form the front panel.
Setup value
Writing
0
Do not write to EEPROM at the same time
1
Write to EEPROM at the same time
Pr6.18
*
Title
Power-up wait time
Related
control mode
P S T F
Range
0 to 100
Unit
0.1s
Default
0
Set up the standard initialization time (1.5 s + α) after power-up.
Pr6.19
*
Title
Encoder Z phase setup
Related
control mode
P S T F
Range
0 to 32767
Unit
pulse
Default
0
If the number of output pulses per one motor revolution after division of pulse output is not
an integer, fine adjust the width of encoder Z phase.
Pr6.20
*
Title
Z-phase setup of external scale
Related
control mode
P S T
F
Range
0 to 400
Unit
μs
Default
0
Set up the Z phase regenerative width of feedback scale in unit of time. Even if the width of
Z phase signal cannot be detected because the width equivalent of the travel distance from
the feedback scale is too short, the Z phase signal will be output for at least the period set to
this parameter.
1. Details of parameter
[Class 6] Special setting
Note
Related page
• For parameters which No. have a suffix of “
*
”
, changed contents will be validated when
you turn on the control power.
• P.2-73 “EEPROM Writing” • P.3-30... “Inputs and outputs on connector X4” • P.6-3 “Protective Function”