2-42
[Class 1] Gain adjustment
Parametr
No.
Title
Range
Default
Unit
Attribute
Related
Control Mode Detail
page
Class No.
A,B
-frame
C
-frame
D,E,F
-frame
INI RO
P S T F
1
00
*
1st gain of position loop
0 to 30000
480
320 0.1/s
P
S T
F
4-12
1
01
*
1st gain of velocity loop
1 to 32767
270
180 0.1Hz
P S T F
1
02
*
1st time constant of velocity loop
integration
1 to 10000
210
310 0.1ms
P S T F
1
03
1st filter of speed detection
0 to 5
0
−
P S T F
1
04
1st time constant of torque filter
0 to 2500
84
126 0.01ms
P S T F
1
05
*
2nd gain of position loop
0 to 30000
570
380 0.1/s
P
S T
F
4-13
1
06
*
2nd gain of velocity loop
1 to 32767
270
180 0.1Hz
P S T F
1
07
*
2nd time constant of velocity loop
integration
1 to 10000
10000
0.1ms
P S T F
1
08
2nd filter of speed detection
0 to 5
0
−
P S T F
1
09
*
2nd time constant of torque filter
0 to 2500
84
126 0.01ms
P S T F
1
10
*
Velocity feed forward gain
0 to 1000
300
0.10%
P
S T
F
1
11
*
Velocity feed forward filter
0 to 6400
50
0.01ms
P
S T
F
1
12
*
Torque feed forward gain
0 to 1000
0
0.10%
P S
T
F
4-14
1
13
*
Torque feed forward filter
0 to 6400
0
0.01ms
P S
T
F
1
14 2nd gain setup
0 to 1
1
−
P S T F
1
15 Mode of position control switching
0 to 10
0
−
P
S T
F
4-15
1
16
*
Delay time of position control switching
0 to 10000
50
0.1ms
P
S T
F
4-16
1
17 Level of position control switching
0 to 20000
50
−
P
S T
F
1
18 Hysteresis at position control switching
0 to 20000
33
−
P
S T
F
1
19
*
Position gain switching time
0 to 10000
33
0.1ms
P
S T
F
1
20 Mode of velocity control switching
0 to 5
0
−
P
S
T F
4-17
1
21
*
Delay time of velocity control switching
0 to 10000
0
0.1ms
P
S
T F
1
22 Level of velocity control switching
0 to 20000
0
−
P
S
T F
1
23 Hysteresis at velocity control switching
0 to 20000
0
−
P
S
T F
1
24 Mode of torque control switching
0 to 3
0
−
P S
T
F
4-18
1
25
*
Delay time of torque control switching
0 to 10000
0
0.1ms
P S
T
F
1
26 Level of torque control switching
0 to 20000
0
−
P S
T
F
1
27 Hysteresis at torque control switching
0 to 20000
0
−
P S
T
F
* Definition of symbols under “Attribute” - INI: turning on of power supply is required, RO: read only
*
Definition of symbols under “Related mode” - P: position control, S: velocity control, T: torque control, F: full closed control
13. Setup of Parameter and Mode
List of Parameters
Caution
Note
The symbol “
*
” attached to a parameter No. indicates that the digits of setting unit will
change if the parameter is set by using the setup support software PANATERM.
Parameter describes of this page is P.4-12 to P.4-18.
Summary of Contents for MINAS A5-series
Page 36: ...1 24 MEMO ...
Page 118: ...2 82 MEMO ...
Page 168: ...3 50 MEMO ...
Page 272: ...5 42 MEMO ...