2-30
Servo-on signal accept timing on power-up
Caution
• The above chart shows the timing from AC power-ON to command input.
• Activate the external command input according to the above timing chart.
*1. In this term Servo-ON input (SRV-ON) turns ON as a hard ware, but operation com-
mand can not be received.
*2. S-RDY output will turn on when both conditions are met, initialization of micro com-
puter has been completed and the main power has been turned on.
*3. After Internal control power supply , protective functions are active from approx. 1.5
sec after the start of initializing microcomputer. Please set the signals, especially for
protective function, for example over-travel inhibit input (POT, NOT) or external scale
input, so as to decide their logic until this term.
The lapse time can be changed with Pr6.18 Wait time after power-up.
Servo-Ready output
(S-RDY)
Servo-ON input
(SRV-ON)
External brake
release output
(BRK-OFF)
output Tr OFF
output Tr ON
input coupler ON
input coupler OFF
Control
power supply
(L1C,L2C)
Internal control
power supply
Action of
driver CPU
Main
power supply
(L1,L2,L3)
Dynamic
brake
Motor
energization
Position/Speed/
Torque command
10ms or longer
*2
10ms or longer
*2
OFF
OFF
ON
reset
(initialization)
usually operation
OFF
ON
output Tr OFF (brake engaged)
ON
(brake released)
released
engaged
not-energized
energized
No command entry
Command
entry
100ms or longer
*1
approx.2s
approx.100 to 300 ms
approx.1.5s
established
approx.60ms
approx.2ms
approx.4ms
0ms or longer
0s or longer
*3
2
Preparation
10.
Timing Chart
Timing on power-up