3-23
1
Before
Using
the
Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When
in
Trouble
7
Supplement
3. Wiring Diagram to the connector, X4
Connecting Example to Host Controller
Note
Related page
represents twisted pair wire.
• P.3-30 “Inputs and outputs on connector X4”
Connection between MINAS A5 and FPG-C32T (Panasonic Electric Works)
Y0
Y1
X2
COM
+
Y2
−
COM
X3
X5
X6
5.6kΩ
3kΩ
5.6kΩ
5.6kΩ
○
○
2kΩ
2kΩ
50
1
4
2
6
19
13
25
7
30
29
27
31
9
8
35
34
37
36
39
38
41
FG
OCP1
PULS2
OCP2
SIGN2
CZ
GND
GND
COM+
CL
SRV-ON
GAIN
A-CLR
POT
NOT
S-RDY+
S-RDY−
ALM+
ALM−
INP+
INP−
COM−
220Ω
220Ω
4.7Ω
4.7Ω
4.7Ω
4.7Ω
4.7Ω
4.7Ω
A5-series
FPG-C32T
(Panasonic Electric Works)
from
PLC I/O
output
to
PLC I/O
input
GND
+ 24V
DC24V
Power supply
Command pulse
input 2
Counter clear input
Servo-ON input
Servo-Ready output
Servo-Alarm output
Positioning complete
output
Alarm clear input
Inhibit negative direction
travel input
Inhibit positive direction
travel input
Z-phase output
Command sign
input 2
Gain switching input
Driver
PLC
CCW limit sensor
Origin proximity sensor
CW limit sensor
CW pulse command
output
CCW pulse command
output
Origin input
Deviation counter
reset output
Origin proximity input
CCW limit excess
input
CW limit excess
input
* Process of shield wire varies with equipment.
Summary of Contents for MINAS A5-series
Page 36: ...1 24 MEMO ...
Page 118: ...2 82 MEMO ...
Page 168: ...3 50 MEMO ...
Page 272: ...5 42 MEMO ...