7-50
4. Communication
Details of Communication Command
command
7
mode
6
• Individual read out of user parameter
Reception data
Property
Transmission data
bit7
Parameter
not in use
6
Display inhibited
5
(for special
customer)
4
Change at
initialization
3
System related
2
1
0
bit15
14
13
12
11
10
9
8
Read only
Front operation
protect
Error code
bit7
0 : Normal
1 : Error
6
5
4
3
2
1
0
Command error
No.Error
RS485 error
• If the parameter type or the parameter No. is outside the range, returns No. error.
• Parameter value, MIN value and MAX value should be sign-extended to 32 bits before being transmitted.
2
axis
parameter type
parameter No.
checksum
7
6
17 (11h)
axis
parameter type
parameter No.
(L)
parameter value
(H)
(L)
MIN value
(H)
(L)
MAX value
(H)
Property L
H
Error code
checksum
7
6
Summary of Contents for MINAS A5-series