6-3
1
Before
Using
the
Products
2
Preparation
3
Connection
4
Setup
5
Adjustment
6
When
in
Trouble
7
Supplement
Note
History...The error will be stored in the error history.
Can be cleared...To cancel the error, use the alarm clear input (A-CLR).
If the alarm clear input is not effective, turn off power, remove the cause of the error and then turn on
power again.
Immediate stop...Instantaneous controlled stop upon occurrence of an error.
(Setting of “Pr.5.10 Sequence at alarm” is also required.)
<List of error code No.>
Error code
Protective function
Attribute
Detail
page
Main Sub
History Can be
cleared
Immediate
stop
11 0 Control power supply under-
voltage protection
6-4
12 0 Over-voltage protection
13
0
Main power supply under-
voltage protection
(between P to N)
1
Main power supply under-
voltage protection
(AC interception detection)
14 0 Over-current protection
6-5
1 IPM error protection
15 0 Over-heat protection
16 0 Over-load protection
18
0 Over-regeneration load protec-
tion
6-6
1 Over-regeneration Tr error
protection
21
0 Encoder communication dis-
connect error protection
1 Encoder communication error
protection
23 0 Encoder communication data
error protection
24
0 Position deviation excess pro-
tection
6-7
1
Velocity deviation excess pro-
tection
25 0 Hybrid deviation excess error
protection
26 0 Over-speed protection
1 2nd over-speed protection
27
0 Command pulse input frequen-
cy error protection
6-8
2 Command pulse multiplier error
protection
28 0 Limit of pulse replay error pro-
tection
29 0
Deviation counter overflow
protection
30 0 Safety detection
33
0 IF overlaps allocation error 1
protection
1 IF overlaps allocation error 2
protection
2 IF input function number error 1
protection
3 IF input function number error 2
protection
4 IF output function number error
1 protection
6-9
5 IF output function number error
2 protection
6
CL fitting error protection
7
INH fitting error protection
34 0 Software limit protection
1. When in Trouble
Protective Function (What is Error Code ?)
Error code
Protective function
Attribute
Detail
page
Main Sub
History Can be
cleared
Immediate
stop
36 0 to
2
EEPROM parameter error pro-
tection
6-9
37 0 to
2
EEPROM check code error
protection
38 0 Over-travel inhibit input protec-
tion
39
0 Analog input1 excess protec-
tion
6-10
1 Analog input2 excess protec-
tion
2 Analog input3 excess protec-
tion
40 0 Absolute system down error
protection
41 0 Absolute counter over error
protection
42 0 Absolute over-speed error pro-
tection
43 0
Initialization failure
44 0 Absolute single turn counter
error protection
45 0 Absolute multi-turn counter er-
ror protection
47 0
Absolute status error protection
6-11
48 0 Encoder Z-phase error protec-
tion
49 0 Encoder CS signal error protec-
tion
50
0 Feedback scale connection er-
ror protection
1 Feedback scale communication
error protection
51
0 Feedback scale status 0 error
protection
1 Feedback scale status 1 error
protection
2 Feedback scale status 2 error
protection
3 Feedback scale status 3 error
protection
4 Feedback scale status 4 error
protection
6-12
5 Feedback scale status 5 error
protection
55
0 A-phase connection error pro-
tection
1 B-phase connection error pro-
tection
2 Z-phase connection error pro-
tection
87 0 Compulsory alarm input protec-
tion
95 0 to 4 Motor automatic recognition
error protection
Other
number Other error
Summary of Contents for MINAS A5-series
Page 36: ...1 24 MEMO ...
Page 118: ...2 82 MEMO ...
Page 168: ...3 50 MEMO ...