7-40
7
4. Communication
Supplement
Details of Communication Command
0Dh
axis
Model of ,motor (upper)
Model of motor (lower)
Error code
checksum
command
0
mode
1
• Read out of CPU version
Reception data
0
axis
checksum
0
1
Error code
Transmission data
• Version information will be returned in upper data and lower data.
(Decimal point will be returned by making the lower 4 bit of the upper dataas 0.)
• Version will be displayed in figures from 0 to 9. (e.g. Version 3.1 will be upper data 30h, lower data 13h.)
bit7
0 : Normal
1 : Error
6
5
Command error
4
RS485 error
3
2
1
0
3
axis
Version (upper)
Version (lower)
Error code
checksum
0
1
command
0
mode
5
• Read out of driver mode
Reception data
0
axis
checksum
0
5
Error code
Transmission data
• Driver model consist of 12-characters, and will be transmitted in ASCII code.
(e.g.) "MADHT1105***"
bit7
0 : Normal
1 : Error
6
5
Command error
4
RS485 error
3
2
1
0
0Dh
axis
Model of driver (upper)
Model of driver (lower)
Error code
checksum
0
5
command
0
mode
6
• Read out of Motor Model
0
axis
checksum
0
6
Error code
Transmission data
• Motor model consist of 12-characters, and will be transmitted in ASCII code.
(e.g.) "MSME012S1***"
bit7
0 : Normal
1 : Error
6
5
Command error
4
RS485 error
3
2
1
0
0Dh
axis
Model of motor (upper)
Model of motor (lower)
Error code
checksum
0
6
Reception data