2-72
For parameters which place is displayed
with “ ”, the content changed and
written to EEPROM becomes valid after
turning off the power once.
• Display the No. of parameter to be
changed and press to change to
EXECUTION display.
• Press and the flashing decimal
separator shifts to the high order position,
allowing the figure at this digit to any other
figure.
(SET button)
• Press or to set up the value of
parameter. (Value increases with
decreases with .)
• Press and the flashing decimal
separator shifts to the high order position,
allowing the figure at this digit to any other
figure.
• Prolonged depression of updates the
parameter in the driver. Note that the
parameter value selected by or is
not reflected until is pressed in this
way.
• To cancel the value selected by or ,
press instead of , and the driver
internal parameter value is kept
unchanged and the display returns to the
parameter number display screen.
After changing the parameter value and
pressing , the content will be reflected in
the control. Do not extremely change the
parameter value which change might affect the
motor movement very much (especially
velocity loop or position loop gains).
(Mode switch button)
(Mode switch button)
Pr0.00
Pr0.00
Pr0.01
Pr6.22
Pr0.01
Pr6.33
• Press or to select parameter No.
to be set.
Parameter No.
(Hexadecimal No.)
Parameter value
Class
Pr0.11
Pr1.11
You can change the
value which digit has
a flashing decimal
point.
SELECTION display
Monitor Mode
SELECTION display
Parameter Setup Mode
SELECTION display
EEPROM Writing
EXECUTION display
Remarks
Note
Note
• After setting up parameters, return to SELECT mode, referring to structure of each mode
(P.2-54).
• Each parameter has a limit in number of places for upper-shifting.
2
Preparation
15. How to Use the Front Panel
Parameter Setup Mode
Summary of Contents for MINAS A5-series
Page 36: ...1 24 MEMO ...
Page 118: ...2 82 MEMO ...
Page 168: ...3 50 MEMO ...
Page 272: ...5 42 MEMO ...