4-58
4
2.Trial Run (JOG run)
Setup
Inspection Before Trial Run
Display LED
Connector X6
ground
Power
supply
Motor
Machine
(1) Inspection on wiring
• Miswiring ? (Especially power input and motor output)
• Short or grounded ?
• Loose connection ?
(2) Confirmation of power supply and voltage
• Rated voltage ?
(3) Fixing of the servo motor
• Unstable mounting ?
(4) Separation from the
mechanical system
(5) Release of the brake
(6) Turn to Servo-OFF after finishing the trial run by pressing .
(1) Inspection on wiring
• Miswiring ? (Especially power input and motor output)
• Short or grounded ?
• Loose connection ?
(2) Confirmation of power supply and voltage
• Rated voltage ?
(3) Fixing of the servo motor
• Unstable mounting ?
(4) Separation from the
mechanical system
(5) Release of the brake
(6) Turn to Servo-OFF after finishing the trial run by pressing .
Note
Details of wiring, refer to P.2-8 “Overall Wiring”
Summary of Contents for MINAS A5-series
Page 36: ...1 24 MEMO ...
Page 118: ...2 82 MEMO ...
Page 168: ...3 50 MEMO ...
Page 272: ...5 42 MEMO ...