I/O Allocation
FP0
5
−
3
5.1
I/O Number
5.1
I/O Number
Expression of numbers for input/output relays
Since input relay (X) and output relay (Y) are handled in units of 16 points, they are
expressed as a combination of decimal and hexadecimal numbers as shown below.
Decimal
1, 2, 3 . . . . . .
Hexadecimal
0, 1, 2, 3
A,B
F
. . . . .
. . . .
X0, X1
XF
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
X10, X11
X1F
. . . . . . . . . . . . . . . . . . . . . . . . .
X20, X21
X2F
. . . . . . . . . . . . . . . . . . . . . . . . .
<Example> External input relay (X)
Specifying X and Y numbers
On the FP0, the same numbers are used for input and output.
Example: The same number “X20 and Y20” can be used for input and output