Optional Memory
FP0
2
−
16
2.2
Specifications
2.2.4
Output Specifications
2.2.4.1
Relay Output Type
FP0 relay output types:
C10RM, C10CRM, C10RS, C10CRS, C14RM, C14CRM,
C14RS, C14CRS
Item
Description
Output type
Normally open (1 Form A) relay output
Rated control capacity
2 A 250 V AC, 2 A 30 V DC (4.5 A maximum per common)
(at Resistance load)
Output points per
common
C10RM,
C10CRM,
C10RS,
C10CRS
2 points/common
+
1 point/1 point/common
C14RM,
C14CRM,
C14RS,
C14CRS
4 points/ 1 point/ 1 point/common
Response time
OFF
→
ON
approx. 10 ms
p
ON
→
OFF
approx. 8 ms
Mechanical life time
20,000,000 operations or more
Electrical life time
100,000 operations or more
Surge absorber
None
Operating mode indicator
LED
Summary of Contents for FP0 Series
Page 14: ...Table of Contents FP0 xii ...
Page 16: ...Overview FP0 1 2 ...
Page 82: ...S LINK Control Unit FP0 4 2 ...
Page 95: ...Chapter 5 I O Allocation 5 1 I O Number 5 3 5 2 Control Unit 5 4 5 3 Expansion I O Unit 5 5 ...
Page 96: ...I O Allocation FP0 5 2 ...
Page 100: ...I O Allocation FP0 5 6 5 3 Expansion I O Unit ...
Page 102: ...Installation FP0 6 2 ...
Page 112: ...Installation FP0 6 12 6 5 Installation Using FP0 Flat Type Mounting Plate ...
Page 114: ...Wiring FP0 7 2 ...
Page 198: ...High speed Counter Pulse Output PWM Output FP0 9 34 9 5 PWM Output Function ...
Page 200: ...General use Serial Communications FP0 10 2 ...
Page 210: ...Self Diagnostic and Troubleshooting FP0 11 2 ...
Page 220: ...Specifications FP0 12 2 ...
Page 234: ...Dimensions FP0 13 2 ...
Page 243: ...Chapter 14 Appendix ...
Page 380: ...14 138 14 7 ASCII Codes ...