14-11
FP0
Item
Add-
ress
Name
Default
value
Descriptions
402
Pulse catch input
function settings
Not set
(H0)
The checked contacts are set as
pulse catch input.
In FP Programmer II, enter the above
settings in hexadecimal.
Example:
When X3 and X4 are set as pulse
catch input
With the FP0, settings X6 and X7 are
invalid.
Using FPWIN GR
The checked contacts are set as
interrupt input.
Input
setting
403
Interrupt input settings
Not set
(H0)
Specify the effective interrupt edge.
(When set: ON
→
OFF is valid)
Using FP Programmer II
Example:
When setting inputs X0, X1, X2 and
X3 as interrupts, and X0 and X1 are
set as interrupt inputs when going
from on to off.
Note1) With the TOOL software, “0” or “1” is set for each bit on the screen in the setting for system
register 403.
Note2) If system register 400 to 403 are set simultaneously for the same inptu relay, the following
precedence order is effective:
[High-speed counter] ‘[Pulse catch]’ [Interrupt input].
When the high-speed counter is being used in the incremental input mode, even if input X0 is
specified as an interrupt input and as pulse catch input, those settings are invalid, and input X0
functions as counter input for the high-speed counter.
No. 400: H1 a This setting will be valid. No. 402: H1 No. 403: H1
Summary of Contents for FP0 Series
Page 14: ...Table of Contents FP0 xii ...
Page 16: ...Overview FP0 1 2 ...
Page 82: ...S LINK Control Unit FP0 4 2 ...
Page 95: ...Chapter 5 I O Allocation 5 1 I O Number 5 3 5 2 Control Unit 5 4 5 3 Expansion I O Unit 5 5 ...
Page 96: ...I O Allocation FP0 5 2 ...
Page 100: ...I O Allocation FP0 5 6 5 3 Expansion I O Unit ...
Page 102: ...Installation FP0 6 2 ...
Page 112: ...Installation FP0 6 12 6 5 Installation Using FP0 Flat Type Mounting Plate ...
Page 114: ...Wiring FP0 7 2 ...
Page 198: ...High speed Counter Pulse Output PWM Output FP0 9 34 9 5 PWM Output Function ...
Page 200: ...General use Serial Communications FP0 10 2 ...
Page 210: ...Self Diagnostic and Troubleshooting FP0 11 2 ...
Page 220: ...Specifications FP0 12 2 ...
Page 234: ...Dimensions FP0 13 2 ...
Page 243: ...Chapter 14 Appendix ...
Page 380: ...14 138 14 7 ASCII Codes ...