Overview
FP0
1
−
5
1.1
Components
1.1.3
Intelligent Units
Product
name
Specifications
Part No.
Product No.
FP0 Ther-
l
K, J, T, R thermocouple, Resolution: 0.1 C
FP0
−
TC4
AFP0420
FP0 Ther
mocouple
Unit
K, J, T, R thermocouple, Resolution: 0.1 C
FP0
−
TC8
AFP0421
FP Web
−
Server unit
Unit for connecting FP series/RS232C interface and Ethernet
Web
−
Server function and E
−
mail sending function
FP
−
WEB
AFP0610
FP0 Analog
Input specifications
Number or channels
Input range
2 channels
: 0 to 5 V,
−
10 to +10 V (Resolution: 1/4000)
0 to 20 mA (Resolution: 1/4000)
FP0
−
A21
AFP0480
FP0 Analog
I/O unit
Output specifications
Number or channels
Output range
1 channels
:
−
10 to +10 V (Resolution: 1/4000)
0 to 20 mA (Resolution: 1/4000)
FP0 A/D
Converter
Unit
Input specifications
Number or channels
Input range
8 channels
: 0 to 5 V,
−
10 to +10 V (Resolution: 1/4000)
0 to 20 mA (Resolution: 1/4000)
FP0
−
A80
AFP0401
FP0 D/A
C
t
Output specifications
Number or channels
Output range
4 channels
:
10 to +10 V (Resolution: 1/4000)
FP0
−
A04V
AFP04121
FP0 D/A
Converter
Unit
p
p
Output range
:
−
10 to +10 V (Resolution: 1/4000)
4 to 20 mA (Resolution: 1/4000)
FP0
−
A04I
AFP04123
1.1.4
Link Units
Product
name
Specifications
Power supply
voltage
Part No.
Product
No.
FP0 CC
−
Link Slave
Unit
This unit is for making the FP0 function as a slave station of the CC
−
Link.
Only one unit can be connected to the furthest right edge of the FP0 expansion bus.
Note: Accuracy will change if an FP0 thermocouple unit is used at the same time.
For details, please refer to the catalog or to the CC
−
Link Unit manual.
24 V DC
FP0
−
CCLS
AFP07943
FP0 I/O Link
Unit
This is a link unit designed to make the FP0 function as a station to MEWNET
−
F
(remote I/O system).
24 V DC
FP0
−
IOL
AFP0732
C
−
NET
adapter S2
type
(for FP0
side)
This is an RS485 adapter designed to allow use of the Computer link function for
connecting to a host computer via C
−
NET. It comes with a 30 cm FP0 tool port
cable. A power supply is not required.
—
—
AFP15402
C
−
NET
adapter
(RS485)
This is an RS485 adapter designed to allow use of the Computer link function for
connecting to a network
−
connected PLC via C
−
NET from a host computer.
100 to 240 V DC
—
AFP8536
adapter
(RS485)
(for com-
puter side)
g
p
24 V DC
—
AFP8532
FP
Web
−
Server
Unit
Connected with FP series PLCs, it conducts Ethernet communication, sends e
−
mail, and displays the
PLC data on HTML pages.
FP
−
WEB
AFP0610
1.1.5
Power Supply Unit
Product name
Specifications
Part No.
Product
No.
FP0 Power supply unit
Input voltage: 100 to 240 V AC
Output: 0.7 A, 24 V DC
FP0
−
PSA4
AFP0634
Summary of Contents for FP0 Series
Page 14: ...Table of Contents FP0 xii ...
Page 16: ...Overview FP0 1 2 ...
Page 82: ...S LINK Control Unit FP0 4 2 ...
Page 95: ...Chapter 5 I O Allocation 5 1 I O Number 5 3 5 2 Control Unit 5 4 5 3 Expansion I O Unit 5 5 ...
Page 96: ...I O Allocation FP0 5 2 ...
Page 100: ...I O Allocation FP0 5 6 5 3 Expansion I O Unit ...
Page 102: ...Installation FP0 6 2 ...
Page 112: ...Installation FP0 6 12 6 5 Installation Using FP0 Flat Type Mounting Plate ...
Page 114: ...Wiring FP0 7 2 ...
Page 198: ...High speed Counter Pulse Output PWM Output FP0 9 34 9 5 PWM Output Function ...
Page 200: ...General use Serial Communications FP0 10 2 ...
Page 210: ...Self Diagnostic and Troubleshooting FP0 11 2 ...
Page 220: ...Specifications FP0 12 2 ...
Page 234: ...Dimensions FP0 13 2 ...
Page 243: ...Chapter 14 Appendix ...
Page 380: ...14 138 14 7 ASCII Codes ...