F0 MV, H 102, DT 100
R21
DF
X2
R20
R20
F0 MV, K1000, DT 101
F0 MV, K6000, DT 102
F0 MV, K 300, DT 103
F1 DMV, K
−
8000, DT 104
F0 MV, K 0, DT 106
R903A
R22
DF
R20
R21
F168 SPD1, DT 100, H 0
DF/
R903A
R22
R22
R20
T1
Positioning operations running
Positioning operations start
Positioning completion pulse (1 s)
TMX 1, K10
High
−
speed Counter/Pulse Output/ PWM Output
FP0
9
−
27
9.4 Pulse Output Function
Relative value positioning operation (minus direction)
When X2 turns on, a pulse is output from Y0. At this time, directional output Y2 turns
on.
DT100
Control code: H102
[refer to “instruction
F168 (SPD1)
”]
DT101
Initial speed: 1000 Hz
DT102
Maximum speed:
6000 Hz
DT103
Acceleration/decelera-
tion time: 300 ms
DT104
DT105
Movement amount:
−
8000 pls
DT106
Pulse stop
Motor
(
−
side)
(+ side)
300 ms
300 ms
6000 Hz
1000 Hz
0 Hz
8000 pulses
8000
pulses
Summary of Contents for FP0 Series
Page 14: ...Table of Contents FP0 xii ...
Page 16: ...Overview FP0 1 2 ...
Page 82: ...S LINK Control Unit FP0 4 2 ...
Page 95: ...Chapter 5 I O Allocation 5 1 I O Number 5 3 5 2 Control Unit 5 4 5 3 Expansion I O Unit 5 5 ...
Page 96: ...I O Allocation FP0 5 2 ...
Page 100: ...I O Allocation FP0 5 6 5 3 Expansion I O Unit ...
Page 102: ...Installation FP0 6 2 ...
Page 112: ...Installation FP0 6 12 6 5 Installation Using FP0 Flat Type Mounting Plate ...
Page 114: ...Wiring FP0 7 2 ...
Page 198: ...High speed Counter Pulse Output PWM Output FP0 9 34 9 5 PWM Output Function ...
Page 200: ...General use Serial Communications FP0 10 2 ...
Page 210: ...Self Diagnostic and Troubleshooting FP0 11 2 ...
Page 220: ...Specifications FP0 12 2 ...
Page 234: ...Dimensions FP0 13 2 ...
Page 243: ...Chapter 14 Appendix ...
Page 380: ...14 138 14 7 ASCII Codes ...