9.3 High
−
speed Counter Function
Positioning operations with a single speed inverter
When X5 is turned on, Y0 turns on and the conveyor begins moving. When the elapsed
value (DT9044 and DT9045) reaches K5000, Y0 turns off and the conveyor stops.
R101
DF
X5
R100
R100
R903A
R102
DF
R100
R101
DF/
R903A
R102
R102
R100
T0
TMX 0, K 5
R101
Y0
S
F1 DMV, K 0, DT 9044
F167 HC1R, K 0, K 5000, Y 0
Positioning operations running
Positioning operations start
Start signal to inverter
Completion pulse
(0.5 seconds)