High
−
level Instructions
3
−
601
Outline
Converts a specified bit column to a bit line.
For the FP0R/FP
Σ
/FP
−
X, the P type high
−
level instruction “P241
(PLINE)” is not available.
Program example
Ladder Diagram
Boolean
Ladder Diagram
Address
Instruction
S
Trigger
D
n
F241 LINE, DT10, K10, DT20
10
R0
10
11
ST
R
0
F241
(LINE)
DT
10
K
10
DT
20
S
Starting address of area where bit column will be read.
n
16-bit equivalent constant or 16-bit area to specify bit position
D
16-bit area for storing converted data (destination)
Operands
Operand
Relay
Timer/Counter
Register
Index
register
Constant
Index
modifier
Integer
device
Operand
WX WY WR WL
SV
EV
DT LD
FL
I
K
H
f
modifier device
S
A
A
A
A
A
A
A
A
A
A
N/A N/A N/A
A
N/A
n
A
A
A
A
A
A
A
A
A
A
A
A
N/A
A
N/A
D
N/A
A
A
A
A
A
A
A
A
A
N/A N/A N/A
A
N/A
F241
P241
(PLINE)
(LINE)
Bit column to bit line conversion
A: Available
N/A: Not Available
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for FP-X
Page 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 2: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 24: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 1333: ...5 245 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...