High
−
level Instructions
3
−
682
Description
The floating point data (32 bits) specified by S is copied to the 32-bit area specified by D when the trigger turns
on.
Floating point data
Real number data
Lower word
DT:
D+1:
15
Higher word
0
Range of real number data which can be set are as follows:
Positive: f0.0000001 to f9999999
Negative: f
−
9999999 to f
−
0.000001
Precaution during programming
For FP0, this instruction
F309 (FMV)
cannot be programmed in the interrupt program.
Flag conditions
・
Error flag (R9007): Turns on and stays on when the area specified using the index modifier
exceeds the limit.
・
Error flag (R9008): Turns on for an instant when the area specified using the index modifier
exceeds the limit.