High
−
level Instructions
3
−
744
Specifying the integer device with [S1], [S2] and [S3], the integer data is internally converted to real numbers
before operations continue.
When the constant K is specified in S1, S2 and S3, the operations are the same as when a integer device is
specified.
Flag conditions
・
Error flag (R9007): Turns on and stays on when:
−
The area specified using the index modifier exceeds the limit.
−
If data other than real number data are specified in “S1+1, S1”, “S2+1, S2”,
and “S3+1, S3”.
−
(S2+1, S2) > (S3+1, S3).
・
Error flag (R9008): Turns on for an instant when:
−
The area specified using the index modifier exceeds the limit.
−
If data other than real number data are specified in “S1+1, S1”, “S2+1, S2”,
and “S3+1, S3”.
−
(S2+1, S2) > (S3+1, S3).