High
−
level Instructions
3
−
760
3) The linear table [S2] must be having the section of two or more points registered.
Moreover, the linear table must be registered in ascending order, from small to large number of the x
sequences.
2 <= Registration mark (m) <= 99
(m=n+1)
xt
−
1 < xt
(1 <= t <= n)
4) When the distance between two points of a scaling table is very large, an operation error occurs.
for example)
Point1: (x
0
,y
0
)=(HFF000000, HFF000000) =(
−
1.7
*
10
34
,
−
1.7
*
10
34
)
Point2: (x
1
,y
1
)=(H7F000000, H7F000000) =(+1.7
*
10
34
, +1.7
*
10
34
)
5) The error of an output result is proportional to the distance between two points of a scaling table.
6) When the integer modifier is specified to be an input value [S1], scaling processing is performed after
changing it into a real numerical value.
7) An output result is changed into an integer value and stored when the integer modifier is specified to be
an output value [S2].
S2:
S2+1:
S2+2:
S2+3:
Registration mark (m)
x0
x1
xn
y0
y1
yn
S2+2n+1:
S2+2n+2:
S2+2n+3:
S2+2n+4:
S2+2n+6:
S2+2n+5:
S2+4:
S2+4n+4:
S2+4n+3:
DT10
DT11
DT12
DT13
DT29
DT30
DT31
DT32
DT33
DT49
DT50
DT14
DT34
Data table(linear table) (S2)
S2 = DT10, n = K10
(real numerical value)
(real numerical value)
(real numerical value)
(real numerical value)
(real numerical value)
(real numerical value)
Input (X)
Output (Y)
Y=[D]
X=[S1]
y
n
−
1
yn
−
2
yn
y
2
y1
y0
Xn
X0 X1 X2
Xn
−
2 Xn
−
1
Flag conditions
・
Error flag (R9007)(R9008):
−
It turns on, when the specified address using the index modifier exceeds a limit.
−
It turns on, when a non
−
real number value is inputted into [S1].
−
In the registration mark of [S2], it turns on at the time of m<2 or m>99.
−
It turns on, when a non
−
real number value is specified to be the real
numerical value (xt, yt) specified in [S2].
−
It turns on, when the linear table of [S2] is not registered in ascending order
of the x
−
sequence.
−
It turns on, when the linear table of [S2] exceeds the area.
−
It turns on, when the overflow (operaion is unable) occurs in the operation of
scaling.
−
It turns on, when integer modifier specification is carried out for [D] and an
output result exceeds the integer range.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for FP-X
Page 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 2: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 24: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 1333: ...5 245 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...