High
−
level Instructions
3
−
740
Specifying the integer device with [S], the integer data is internally converted to real numbers before
operations continue.
F338 DEG, % DT 0, DT 4
R0
Specifying the integer device with [D], the real numbers are automatically converted into integer data.
F338 DEG, DT 0, % DT 4
R0
When the constant K is specified in S, the operations are the same as when a integer device is specified.
Program example
The “f30.00000” is stored to DT20 and DT21 when the R0 turns on.
F338 DEG, f0.5235987, DT20
R0
Precautions during programming
When the constant or integer device is specified in S, the integer device cannot be set in D.
For FP0, this instruction
F338 (DEG)
cannot be programmed in the interrupt program.
Flag conditions
・
Error flag (R9007): Turns on and stays on when:
・
Error flag (R9008): Turns on for an instant when:
−
The area specified using the index modifier exceeds the limit.
−
If data other than real number data is specified in S+1 and S.
−
If result of processing is outside integer range when integer device specified
in D+1 and D.
・
= flag (R900B):
Turns on when result of processing is recognized as “0.”
・
Carry flag (R9009): Turns on for an instant when the result is overflowed.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for FP-X
Page 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 2: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 24: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 1333: ...5 245 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...