5-97
(A: Available, N/A: Not available)
Register
No.
Name
Descriptions
Read
-ing
Writ-
ing
DT90052
High-speed counter
and pulse output
control flag
A value can be written with F0 (MV) instruction
to reset the high-speed counter, disable
counting, continue or clear high-speed counter
instruction.
Control code setting
Note) Refer to the “Count for reset input” in
“Count 6.3.2 “Input Mode and Count”
N/A A
DT90053
Real-Time Clock
(Clock/Calendar)
monitor (hour/minute)
Hour and minute data of the Real-Time Clock
(Clock/Calendar) are stored here. This data is
read-only data. It cannot be overwritten.
A N/A
DT90054
Real-Time Clock
(Clock/Calendar)
setting
(minute/second)
DT90055
Real-Time Clock
(Clock/Calendar)
setting (day/hour)
DT90056
Real-Time
Clock(Clock/Calendar)
setting (year/month)
DT90057
Real-Time Clock
(Clock/Calendar)
setting (day-of-the-
week)
The year, month, day, hour, minute, second
and day-of-the-week data for the Real-Time
Clock(Clock/Calendar) is stored.
The built-in Real-Time Clock(Clock/Calendar)
will operate correctly through the year 2099
and supports leap years. The Real-Time Clock
(Clock/Calendar) can be set by writing a value
using a programming tool software or a
program that uses the F0 (MV) instruction.(see
example for DT90058)
As a day of the week is not automatially set on
FPWIN GR, fix what day is set to 00, and set
each value for 00 to 06.
A A
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for FP-X
Page 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 2: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 24: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 1333: ...5 245 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...