5-208
Name
Boolean
Symbol
Description
St
e
ps
FP-
e
FP0
FP0
R
FP
Σ
FP-
X
FP2
FP2
S
H/FP1
0
S
H
STF=
Begins a logic operation by comparing two 32-
bit data in the comparative condition “(S1+1,
S1)=(S2+1, S2)”.
9
*1
*1
STF<>
Begins a logic operation by comparing two 32-
bit data in the comparative condition “(S1+1,
S1)<(S2+1, S2)” or “(S1+1, S1)>(S2+1, S2)”.
9
*1
*1
STF>
Begins a logic operation by comparing two 32-
bit data in the comparative condition “(S1+1,
S1)>(S2+1, S2)”.
9
*1
*1
STF>=
Begins a logic operation by comparing two 32-
bit data in the comparative condition “(S1+1,
S1)>(S2+1, S2)” or “(S1+1, S1)=(S2+1, S2)”.
9
*1
*1
STF<
Begins a logic operation by comparing two 32-
bit data in the comparative condition “(S1+1,
S1)<(S2+1, S2)”.
9
*1
*1
Floating
point
type real
number
data
compare
(Start)
STF<=
Begins a logic operation by comparing two 32-
bit data in the comparative condition “(S1+1,
S1)<(S2+1, S2)” or “(S1+1, S1)=(S2+1, S2)”.
9
*1
*1
ANF=
Connects a Form A (normally open) contact
serially by comparing two 32-bit data in the
comparative condition “(S1+1, S1)=(S2+1, S2)”.
9
*1
*1
ANF<>
Connects a Form A (normally open) contact
serially by comparing two 32-bit data in the
comparative condition “(S1+1, S1)<(S2+1, S2)”
or “(S1+1, S1)>(S2+1, S2)”.
9
*1
*1
ANF>
Connects a Form A (normally open) contact
serially by comparing two 32-bit data in the
comparative condition “(S1+1, S1)>(S2+1, S2)”.
9
*1
*1
ANF>=
Connects a Form A (normally open) contact
serially by comparing two 32-bit data in the
comparative condition “(S1+1, S1)>(S2+1, S2)”
or “(S1+1, S1)=(S2+1, S2)”.
9
*1
*1
ANF<
Connects a Form A (normally open) contact
serially by comparing two 32-bit data in the
comparative condition “(S1+1, S1)<(S2+1, S2)”.
9
*1
*1
Floating
point
type real
number
data
compare
(AND)
ANF<=
Connects a Form A (normally open) contact
serially by comparing two 32-bit data in the
comparative condition “(S1+1, S1)<(S2+1, S2)”
or “(S1+1, S1)=(S2+1, S2)”.
9
*1
*1
ORF=
Connects a Form A (normally open) contact in
parallel by comparing two 32-bit data in the
comparative condition “(S1+1, S1)=(S2+1, S2)”.
9
*1
*1
ORF<>
Connects a Form A (normally open) contact in
parallel by comparing two 32-bit data in the
comparative condition “(S1+1, S1)<(S2+1, S2)”
or “(S1+1, S1)>(S2+1, S2)”.
9
*1
*1
ORF>
Connects a Form A (normally open) contact in
parallel by comparing two 32-bit data in the
comparative condition “(S1+1, S1)>(S2+1, S2)”.
9
*1
*1
ORF>=
Connects a Form A (normally open) contact in
parallel by comparing two 32-bit data in the
comparative condition “(S1+1, S1)>(S2+1, S2)”
or “(S1+1, S1)=(S2+1, S2)”.
9
*1
*1
ORF<
Connects a Form A (normally open) contact in
parallel by comparing two 32-bit data in the
comparative condition “(S1+1, S1)<(S2+1, S2)”.
9
*1
*1
Floating
point
type real
number
data
compare
(OR)
ORF<=
Connects a Form A (normally open) contact in
parallel by comparing two 32-bit data in the
comparative condition “(S1+1, S1)<(S2+1, S2)”
or “(S1+1, S1)=(S2+1, S2)”.
9
*1
*1
: Available, : Not available,
: Not available partially
*1) This instruction is available for FP-X V1.10 or later and FP
Σ
32k type
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for FP-X
Page 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 2: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 24: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 1333: ...5 245 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...