5-207
Name
Boolean
Symbol
Description
St
e
ps
FP-
e
FP0
FP0
R
FP
Σ
FP-
X
FP2
FP2
S
H/FP1
0
S
H
STD=
Begins a logic operation by comparing two 32-
bit data in the comparative condition “(S1+1,
S1)=(S2+1, S2)”.
9
STD<>
Begins a logic operation by comparing two 32-
bit data in the comparative condition “(S1+1,
S1)<(S2+1, S2)” or “(S1+1, S1)>(S2+1, S2)”.
9
STD>
Begins a logic operation by comparing two 32-
bit data in the comparative condition “(S1+1,
S1)>(S2+1, S2)”.
9
STD>=
Begins a logic operation by comparing two 32-
bit data in the comparative condition “(S1+1,
S1)>(S2+1, S2)” or “(S1+1, S1)=(S2+1, S2)”.
9
STD<
Begins a logic operation by comparing two 32-
bit data in the comparative condition “(S1+1,
S1)<(S2+1, S2)”.
9
32-bit
data
compare
(Start)
STD<=
Begins a logic operation by comparing two 32-
bit data in the comparative condition “(S1+1,
S1)<(S2+1, S2)” or “(S1+1, S1)=(S2+1, S2)”.
9
AND=
Connects a Form A (normally open) contact
serially by comparing two 32-bit data in the
comparative condition “(S1+1, S1)=(S2+1, S2)”.
9
AND<>
Connects a Form A (normally open) contact
serially by comparing two 32-bit data in the
comparative condition “(S1+1, S1)<(S2+1, S2)”
or “(S1+1, S1)>(S2+1, S2)”.
9
AND>
Connects a Form A (normally open) contact
serially by comparing two 32-bit data in the
comparative condition “(S1+1, S1)>(S2+1, S2)”.
9
AND>=
Connects a Form A (normally open) contact
serially by comparing two 32-bit data in the
comparative condition “(S1+1, S1)>(S2+1, S2)”
or “(S1+1, S1)=(S2+1, S2)”.
9
AND<
Connects a Form A (normally open) contact
serially by comparing two 32-bit data in the
comparative condition “(S1+1, S1)<(S2+1, S2)”.
9
32-bit
data
compare
(AND)
AND<=
Connects a Form A (normally open) contact
serially by comparing two 32-bit data in the
comparative condition “(S1+1, S1)<(S2+1, S2)”
or “(S1+1, S1)=(S2+1, S2)”.
9
ORD=
Connects a Form A (normally open) contact in
parallel by comparing two 32-bit data in the
comparative condition “(S1+1, S1)=(S2+1, S2)”.
9
ORD<>
Connects a Form A (normally open) contact in
parallel by comparing two 32-bit data in the
comparative condition “(S1+1, S1)<(S2+1, S2)”
or “(S1+1, S1)>(S2+1, S2)”.
9
ORD>
Connects a Form A (normally open) contact in
parallel by comparing two 32-bit data in the
comparative condition “(S1+1, S1)>(S2+1, S2)”.
9
ORD>=
Connects a Form A (normally open) contact in
parallel by comparing two 32-bit data in the
comparative condition “(S1+1, S1)>(S2+1, S2)”
or “(S1+1, S1)=(S2+1, S2)”.
9
ORD<
Connects a Form A (normally open) contact in
parallel by comparing two 32-bit data in the
comparative condition “(S1+1, S1)<(S2+1, S2)”.
9
32-bit
data
compare
(OR)
ORD<=
Connects a Form A (normally open) contact in
parallel by comparing two 32-bit data in the
comparative condition “(S1+1, S1)<(S2+1, S2)”
or “(S1+1, S1)=(S2+1, S2)”.
9
: Available, : Not available,
: Not available partially
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for FP-X
Page 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 2: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 24: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 1333: ...5 245 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...