High
−
level Instructions
3
−
576
Explanation of example
When trigger R0 turns on,
−
the contents of data register DT10 are copied to DT40.
−
the contents of data register DT20 are copied to DT41.
−
the contents of data register DT30 are copied to DT42.
Contents of DT30
DT41
DT42
[S3]16 bits
[S1]16 bits
Contents of DT10
[S2]16 bits
Contents of DT20
DT40
[D]
Description
The 16-bit data or 16-bit equivalent constant specified by S1, S2 and S3 is copied to the area (3 words)
specified by D when the trigger turns on.
Related instruction
To transfer two types of 16-bit data at once, use the
F7 (MV2)
instruction.
Flag conditions
・
Error flag (R9007): Turns on and stays on when the area specified using the index modifier
exceeds the limit.
・
Error flag (R9008): Turns on for an instant when the area specified using the index modifier
exceeds the limit.