High
−
level Instructions
3
−
457
*1: Specification of high
−
speed counter channel
Specify the channel of the high
−
speed counter/pulse output with H constant in the starting area (2 words) of
the data table.
H 0 0 0 0 0 0 0 1
<Specification of the channel of high
−
speed counter/pulse output>
Allowable range for specifying the high
−
speed counter: 0 to 5
Specification of maximum value control:0 = Not control with the maximum target value
1 = Control with the maximum target value
<Specification of high
−
speed counter/pulse output>
0: Specification of high
−
speed counter
*2: Specify the word number of the internal relay where the targe position is output. (Note1)
In the 3rd word and 4th word areas, specify the word number of the internal relay where the target position is
output.
*3: Specification of the number of target positions (Note1)
Specify the number of target positions. Settable range: K1 to K31
<Method of target position notification>
1514131211 10 9 8 7 6 5 4 3 2 1 0
WRn
WRn+1
Turns on when the elapsed value matches the first target value.
Turns on when it matches the 17th target value.
Turns on when it matches
the 15th target value.
Turns on when this instruction is executed. Only when the current value is
smaller than target posit
When the number of the target values is in the range of 1 to 16, 1 word is used.
When the number of the target values is in the range of 17 to 32, 2 words are used.
Values in specified in “S+2” and “S+3”
*4: Specification of target position: Specify the target position after the 5th word.
Settable range: K
−
2147483648 to K2147483647
(H80000000 to H7FFFFFFF)
*5: Specification of maximum target value: Specify the maximum target value in the next address of the targe
value at the final target position.
Settable range: K
−
2147483648 to K2147483647
(H80000000 to H7FFFFFFF)
The interrupt program INTn corresponding to the specified high
−
speed counter channel can be executed at
the target position.
The interrupt program corresponding to the channel to be controlled is programmed.
After this instruction is executed, interrupt will be permitted with ICTL instruction.
Note1) Specify numbers so that the total of them does not exceed the maximum area of the internal relay.
FP0R
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for FP-X
Page 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 2: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 24: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 1333: ...5 245 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...