High
−
level Instructions
3
−
518
Setting the d
ata table
S
S+
1
Control code
S+
2
S+
3
Initial speed
(Hz)
Velocity range (Frequency) (Hz)
S+
4
S+
5
Target speed 1
(Hz)
Velocity range (Frequency) (Hz)
1Hz to 50kHz [K1 to K50000 (Unit: Hz)]
S+
6
S+
7
Acceleration time
(ms)
Acceleration/deceleration time range (ms)
K1 to K32760 (Unit: ms)
S+
8
S+
9
Target speed 2
(Hz)
Velocity range (Frequency) (Hz)
1Hz to 50kHz [K1 to K50000 (Unit: Hz)]
S+
10
S+
11
Change time
(ms)
K1 to K32760 (Unit: ms)
S+
12
S+
13
Deceleration time
(ms)
K1 to K32760 (Unit: ms)
S+
14
S+
15
Target value
(No. of pulses)
Target value range
K
−
2,147,483,648 to K2,147,483,647
Note the following characteristics according to the specified initial speed.
(1) When the initial speed is 1 or higher, and lower than 46Hz, the control up to the maximum frequency to the
degree of 10kHz can be performed.
If the frequency is higher than that, the speed error will be larger.
(2) When the initial speed is 46 or higher, and lower than 184Hz, the control up to 50kHz can be performed.
(3) When the initial speed is 184 or higher, the control up to 50kHz can be performed.
The speed error around 50kHz will be smallest.
FP0R
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for FP-X
Page 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 2: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 24: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 1333: ...5 245 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...