High
−
level Instructions
3
−
158
Outline
Converts 16-bit data to ASCII code that expresses the equivalent
hexadecimals.
For the FP0R/FP
Σ
/FP
−
X/FP0/FP
−
e, the P type high
−
level instruction
“P71 (PHEXA)” is not available.
Program example
Ladder Diagram
Boolean
Ladder Diagram
Address
Instruction
10
F71 HEXA , DT 0 , K 2 , DT 10
S1
D
Trigger
S2
R0
10
11
ST
R
0
F 71
(HEXA)
DT
0
K
2
DT
10
S1
Starting 16-bit area for hexadecimal number (source)
S2
16-bit equivalent constant or 16-bit area to specify number of source data
bytes to be converted
D
Starting 16-bit area for storing ASCII code (destination)
Operands
Operand
Relay
Timer/Counter
Register
Index
register
Constant
Index
Operand
WX WY WR WL
(
*
1)
SV
EV
DT LD
(
*
1)
FL
(
*
2)
IX
(
*
3)
IY
(
*
4)
K
H
Index
modifier
S1
A
A
A
A
A
A
A
A
A
N/A
N/A
N/A N/A
A
S2
A
A
A
A
A
A
A
A
A
A
A
A
A
A
D
N/A
A
A
A
A
A
A
A
A
N/A
N/A
N/A N/A
A
(
*
1) This cannot be used with the FP0 and FP
−
e.
(
*
2) This cannot be used with the FP0, FP
−
e, FP0R, FP
Σ,
FP
−
X.
(
*
3) With the FP0R, FP
Σ
, FP
−
X, FP2, FP2SH, and FP10SH, this is I0 to IC.
(
*
4) With the FP0R, FP
Σ
, FP
−
X, FP2, FP2SH, and FP10SH, this is ID.
F71
P71
(PHEXA)
(HEXA)
Hexadecimal data
→
ASCII code
A: Available
N/A: Not Available
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for FP-X
Page 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 2: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 24: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 1333: ...5 245 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...