5-42
FP-e (A: Available, N/A: Not available)
Register
No.
Name
Descriptions
Read
-ing
Writ
-ing
DT9104
DT9105
High-speed
counter
elapsed
value
For
ch2
The elapsed value (24-bit data) for the high-
speed conter is stored here. The value can be
read and written by executing the F1 (DMV)
instruciton.
A A
DT9106
DT9107
High-speed
counter
target value
For
ch2
The target valeu (24-bit data) of the high-speed
counter specified by the high-speed counter
instruction is stored here.
Target values have been preset for the various
instructions, to be used when the high-speed
counter related instruction is executed. The
value can be read by executing the F1 (DMV)
instruction.
A N/A
DT9108
DT9109
High-speed
counter
elapsed
value
For
ch3
The elapsed value (24-bit data) for the high-
speed counter is stored here. The value can be
read and written by executing the F1 (DMV)
instruction.
A A
DT9110
DT9111
High-speed
counter
target value
For
ch3
The target value (24-bit data) of the high-speed
counter specified by the high-speed counter
instruction is stored here.
Target values have been preset for the various
instructions, to be used when the high-speed
counter related instruction is executed. The
value can be read by executing the F1 (DMV)
instruction.
A N/A
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Summary of Contents for FP-X
Page 1: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 2: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 24: ...Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...
Page 1333: ...5 245 Phone 800 894 0412 Fax 888 723 4773 Web www clrwtr com Email info clrwtr com ...