Explanation of example
The contents of data register DT10 and data register DT22 are exchanged when trigger R0 turns on.
DT20
DT21
DT22
DT23
DT24
K
21
K
11
K
10
K
12
[D1] DT10
DT11
DT12
DT13
DT14
K
20
K
22
DT20
DT21
DT22
DT23
DT24
R0: on
“
F15 (XCH)
” execution
K
23
K
13
K
14
K
24
K
21
K
11
K
22
K
12
[D1] DT10
DT11
DT12
DT13
DT14
K
20
K
10
K
23
K
13
K
14
K
24
[D2]
[D2]
Description
The contents in the 16-bit areas specified by D1 and D2 are exchanged.
Flag conditions
・
Error flag (R9007): Turns on and stays on when the area specified using the index modifier
exceeds the limit.
・
Error flag (R9008): Turns on for an instant when the area specified using the index modifier
exceeds the limit.